Structured cabling
Copper and fibre cabling, labelled, tested and documented.

Fibre, OTDR & transmission
Fusion splicing, OTDR traces, fault location, circuit acceptance testing and transmission equipment work, for carriers, data centres and enterprises.
Fibre work
When a fibre link fails or underperforms, you need to know where and why, not just that it is down. IITECH engineers use OTDR and light-level testing to find breaks, bad splices, tight bends and dirty connectors. Then we fix them and prove the repair with a fresh trace.
We also work on the carrier side. That means BER and RFC 2544 testing for circuit acceptance, and installs, patching and card swaps on SDH and DWDM transmission equipment. The engineer who splices your fibre understands the equipment that runs over it.
Johannesburg and Gauteng work is our day-to-day. Fibre work elsewhere in South Africa, and on request across Africa, is planned with you.

Services
From a single dirty connector to a full route of splices.
Got a task or ticket for us?Send the site, the task and your time window on WhatsApp.
WhatsApp +27 78 243 6482How it works
Baseline, fix, prove.
You share the route, link IDs, end points and any existing traces or records.
We test from the relevant end points to baseline the link and locate the problem.
We splice, re-terminate or clean, depending on the fault, and keep you updated.
A new trace and loss results confirm the fix and go into your report.
Response times and SLAs. We take 24/7 emergency fibre callouts. Callouts and planned work are covered by response targets we agree with you in advance, based on location and access. We confirm them in writing, not as a headline number.
FAQ
Something else you need to know? Ask an engineer directly.
An optical time-domain reflectometer sends light pulses down a fibre and measures what reflects back. The trace shows the distance to splices, connectors, bends and breaks, and how much loss each one causes.
Yes. We do fusion splicing across Johannesburg and Gauteng, in buildings, comms rooms, data centres and on campus routes, and further afield by arrangement.
Yes. We test from one or both ends, locate the fault on the trace, repair it, then re-test and give you the before-and-after results.
BER testing checks a circuit for bit errors over time. RFC 2544 is a standard set of tests for throughput, latency, frame loss and back-to-back frames. Both are used to accept new circuits and to troubleshoot.
Yes. You get the trace files and a summary report, ready to attach to your ticket or hand-over pack.
Related
Copper and fibre cabling, labelled, tested and documented.
Rack and stack, installs, decommissions and audits.
Reboots, swaps, patching and checks on your equipment, 24/7.
Cisco, Aruba, Arista, SD-WAN and Wi-Fi installs and fixes.
See all IITECH services · Services overview · About IITECH
Product and company names on this page are trademarks of their respective owners and are used only to describe the equipment, platforms and environments we work on.

Let's talk
Tell us the site, the task and your time window. An engineer will get back to you, day or night.
+27 78 243 6482hello@iitech.co.zaJohannesburg, Gauteng